Pneumatic
Lubrication
Hydraulic
Electrical
Check Valves


Unit Dimensions
Line mounting valve
|
Size NG |
D1 |
L1 |
T1 |
A/F |
WT |
T2 |
|
06 |
G 1/4 |
58 |
12 |
19 |
0.10 |
15 |
|
10 |
G 1/2 |
72 |
14 |
30 |
0.30 |
19 |
|
16 |
G 3/4 |
85 |
17 |
36 |
0.47 |
23 |
|
20 |
G1 |
98 |
21 |
46 |
0,88 |
26 |
|
30 |
G1-1/2 |
132 |
31 |
65 |
2,40 |
39 |

Technical Specification
- Construction
- Flow direction
- Mounting style
- Viscosity range
- Hydraulic medium
- Operating pressure
- Fluid temperature range
- Fluid cleanliness requirament
- Nominal flow handling capacity
- Cracking pressure available In
- Line Mounting
Seat type
- Free (low. from Port A toB Leakage free closure in opposite direction
- In line mounting
- 10 Cst to 380 Cst
- Mineral Oil
- 315 Bar
- -20 to +70 degree C
- As per ISO Code 16/13 or better
|
Size NG |
Flow (L.P.M.) |
|
06 |
10 |
|
10 |
20 |
|
16 |
30 |
|
20 |
120 |
|
30 |
280 |
|
Size NG |
Row (L.RM.) |
|
06 |
0.1 |
|
10 |
0.31 |
|
16 |
0.63 |
|
20 |
0.95 |
|
30 |
2.30 |
0.5 , 1 , 2 , 3 , or 5 Bar
Ordering Code